Dome Flat Setting and Appropriate Exposure Time 2006.01.04 updated
Note: top screens should be moved to domeflat position (17,1.5)
(3, 1.5) is not acceptable.
Band Volt Ampare Exp MIT Date Note
B 6.0 6.33 15 12000 2001.4.24 10W lamp
V 4.0 5.10 15 11000 2001.4.25 10W lamp
20 14000 2001.5.20 10W lamp
R 2.5 3.97 30 8200 2001.4.18 10W lamp
2.96 4.36 15 10000 2001.4.24 10W lamp
I 2.7 4.1 15 19400 2001.4.23 10W lamp
g' 5.00 5.72 10 10000 2002.10.16 10W lamp
r' 3.00 4.34 15 10300 2002.10.16 10W lamp
i' 2.7 4.11 10 13360 2001.4.25 10W lamp
z' 2.61 4.08 10 14000 2001.5.20 10W lamp
NA503 6.0 6.33 70 10000 2001.4.23 10W lamp
NA659 6.0 6.33 20 20000 2001.4.24 10W lamp
NB816 6.0 6.3 10 18300 2001.6.24 10W lamp
8 15000 2002.4.4
NB711 6.0 6.3 20 17100 2001.6.24 10W lamp
IA827 2.70 4.15 30 11000 2002.2.15 10W lamp
U 6.0 6.3 120 1900 2002.3.14 10W lamp
80 4.0 20 10000 2002.3.14 600W lamp
NB570 6.0 6.3 40 12000 2002.3.16 10W lamp
NB921 6.0 6.3 10 13000 2002.4.5 10W lamp
NB912 6.0 6.3 10 12000 2002.9.6 10W lamp
IA651 5.0 5.72 10 15000 2002.11.3 10W lamp : need confirmation
NB497 6.0 6.33 60 8900 2004.04.20 10W
NB497 6.0 6.33 90 13000 2004.04.20 10W
IA427 6.0 6.33 100 10200 2005.02.11 10W
IA709 5.0 5.72 10 22000 2005.02.11 10W
4.0 5.10 10 10300
VR 3.0 4.36 15 9600 2005.03.10 10W
3.0 4.34 15 9200 2005.06.06 10W
4.0 5.10 15 > 30000
NA671 6.0 6.33 15 17500 2006.01.04 10W